TOXFREE ZH RZ1MZ1-K (AS)
Description
Halogen free (LSZH) armoured cable with galvanized steel wire armour.
The safety cable TOXFREE ZH RZ1MZ1-K (AS) is an LSZH. It doesn't release harmful or corrosive gases in the event of a fire, safeguarding the public's health and preventing potential harm to electronic devices. Its use is therefore strongly advised for public areas, hazardous areas with explosive gas atmospheres (ATEX), and installations in general where there is a chance of mechanical aggression to the cable.
Performance of the TOXFREE ZH RZ1MZ1-K (AS) cable
Electrical functionality
MINIMUM VOLTAGE 0,6/1kV
Typical
IEC 60502-1
Acceptances
RoHS and CE
Regulations for CPR Construction Products CCA S1b, D1, and A1
Thermal efficiency
90ºC is the maximum conductor temperature.
250ºC is the maximum short-circuit temperature (maximum 5 s).
Per GOST 31996, the minimum service temperature is -50 °C.
0 °C is the minimum temperature required for handling and installation.
Performance of fire
non-propagation of flames according to IEC 60332-1 and EN 60332-1.
According to EN 60332-3, IEC 60332-3, and EN 50399, fire does not spread.
Low Smoke Halogen Free, or LSHF, is compliant with IEC 60754-1 and EN 60754-1.
According to EN 61034 and IEC 61034, low smoke emissions: Transmittance of light > 60%
low emissions of corrosive gases in accordance with IEC 60754-2 and EN 60754-2.
CCA s1a, d1, a1 in response to fire CPR, as per EN 50575.
Performance of mechanical systems
A cable diameter of x10 is the minimum bending radius.
AG4 High severity is the impact resistance rating.
Proof against rodents
Performance of chemicals
Resistance to chemicals and oil: Acceptable.
resistant to hydrocarbons.
Resistance to UV: EN 50168.
locations that could be explosive hazards. (ATEX)
Performance of water
AD5 Jets are water resistant.
Other
marking from meter to meter.
Conditions of installation
Outside.
buried.
in a conduit.
Uses
industrial application.
locations that could be explosive hazards. (ATEX)
Design of the TOXFREE ZH RZ1MZ1-K (AS) cable
The conductor
Class 5 (flexible) electrolytically annealed copper, according to EN 60228 and IEC 60228.
Insulation
HD 603 defines cross-linked polyethylene (XLPE) as type DIX-3, while IEC 60502-1 defines it as type XLPE.
In accordance with HD 308, insulated conductors are typically identified as follows:
One natural
Two times Brown + Blue
3 G Green/yellow + Brown + Blue
Three x Black + Grey + Brown
4 G: Green/yellow + Black + Grey + Brown
Four times: Brown, Black, Grey, and Blue
Five grams of brown, black, grey, blue, and green or yellow
At least six black-numbered plus green or yellow
Armour bedding
Polyolefin inner sheath with low smoke halogen free (LSHF) properties.
Armor
Armour made of galvanized steel wire.Single-core cables use aluminum armor to prevent parasite currents that could cause the cable to overheat.
External sheath
IEC 60502-1 classifies this polyolefin as type ST8, or low smoke halogen free. Fire retardant, non-toxic, and black in color.
LOW VOLTAGE 0,6/1kV
EN 60332-1 / EN 60332-3
Cca-s1b, d1, a1
Maximum conductor temperature: 90ºC.
Industral use / Potentially explosion hazard locations. (ATEX)
Technology
1. Class 5 (flexible) conductor electrolytic copper, according to EN and IEC 60228.
2. Warmth
XLPE, or cross-linked polyethylene.
Insulated conductors are typically identified as follows:
One natural
Two x Brown + Blue
3 G Green/Yellow + Brown + Blue
Three x Brown, Black, and Grey
4 G Yellow/green + Black + Grey + Brown
Four times: Brown, Black, Grey, and Blue
Five grams of brown, black, grey, blue, and yellow/green
Six or more Black digits plus green/yellow
3. Low smoke halogen free (LSHF) polyolefin inner sheath for armor bedding.
4. Armour Armour made of galvanized steel wire. Single-core cables use aluminum armor to prevent parasite currents that could cause the cable to overheat.
5. IEC 60502-compliant outer sheath Low Smoke Halogen Free (LSHF) polyolefin, type ST81. Non-toxic, fire retardant, and black in color.
Cable Specifications
ENVIRONMENTAL PERFORMANCE
- Chemical & Oil resistance: Acceptable.
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 0,6/1kV
MECHANICAL PERFORMANCE
- Impact resistance: AG4 High severity.
- Minimum bending radius: x10 cable diameter.
- Rodent proof
WATER RESISTANCE
- Water resistance: AD5 Jets.
CHEMICAL PERFORMANCE
- Potentially explosion hazard locations. (ATEX)
- UV Resistant: based on UNE 211605.
FIRE PERFORMANCE
- Fire non-propagation based on EN 60332-3 / IEC 60332-3 / EN 50399.
- Flame non-propagation based on EN 60332-1 and IEC 60332-1
- Low corrosive gases emission according to IEC 60754-2
- Low smoke emission according to EN 61034 and IEC 61034.: Light transmittance > 60%
- Low smoke halogen free according to IEC 60754-1
- Reaction to fire CPR: Cca-s1b, d1, a1 according to EN 50575.
THERMAL PERFORMANCE
- Maximum service temperature: 90ºC.
- Maximum short-circuit temperature: 250ºC (max. 5 s).
- Minimum service temperature: -50 °C according to GOST 31996.
- Minimum service temperature: 0ºC.
APPLICATIONS
- Industrial use.
- Potentially explosion hazard locations. (ATEX)
INSTALLATION CONDITIONS
- Buried
- In conduit.
- Open Air.
CONSTRUCTION PRODUCT REGULATION
- Cca-s1b, d1, a1
International norm
- IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034
APPROVALS
- CE
- RoHS
BASED ON
- IEC 60502-1
National norm / European:
- EN 60332-1 / EN 60332-3
OTHERS
- Meter by meter marking.
Reviews