XTREM DN-F
Description
XTREM DN-F cables are flexible and rubberized, making them perfect for demanding mobility applications. Building sites, agricultural exploitations, hazardous areas with explosive gas atmospheres, motors, and portable machinery can all use it. It can also be installed outdoors and in dry, damp, or rainy conditions.
XTREM DN-F cables' electrical capability and performance
LOWEST VOLTAGE: 1.8/3kV
Typical
UNE 21150
Acceptances
CE/RoHS
Construction Product Regulation (CPR)
Eca
Efficiency of heat
The maximum service temperature is 90ºC.
The highest short-circuit temperature (maximum 5 s) is 250ºC.
The minimum service temperature for shielded and fixed installations is -40°C; for mobile use, it is -25°C.
Fire performance
IEC 60332-1 and UNE-EN 60332-1 state that flames do not spread.
Eca is the fire CPR response in line with EN 50575.
Mechanical system performance
The minimal bending radius is smaller than 12 mm, which is three times the cable diameter.
Four cables with a diameter of more than 12 mm each.
The AG2 impact resistance is medium.
Chemical performance
outstanding oil and chemical resistance.
outstanding resistance to grease and mineral oils.
Water's performance
Water resistance: AD8 Submersion.
immersed pumps.
in drinkable water that complies with AS/NZS 4020.
deep wells.
drinkable water.
AWQC. Extra
meter-to-meter marker.
Installation conditions
Outside.
Applications of submersible pump cables
industrial use.
usage while traveling.
robotics.
windmills.
agricultural exploitation.
installations on makeshift locations.
Packing
available in 100-meter rolls and barrels.
XTREM DN-F cable design conductor
Electrolytic copper of class 5 (flexible), according to EN 60228 and IEC 60228.
Insulation
Rubber (EPR variety)
The following is the standard identification in line with HD 308:
Just One Natural
Brown + Blue x Two
3 G Brown + Blue + Green/Yellow
Three Black, Grey, and Brown
4 G Black + Grey + Brown + Yellow/Green
Brown, Black, Grey, and Blue four times
5 G Grey + Blue + Brown + Negro + Yellow/Green
At least six Flexible rubber with black numbers and an outer sheath that is green or yellow. The hue black
Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1. Reaction to fire CPR: Eca , according to EN 50575.
Eca
Minimum bending radius: 3 x cable diameter 12 mm.
Technology
1. Electrolytic copper, a Class 5 (flexible) conductor as defined by EN and IEC 60228.
2. Rubber insulation (per EN 50363-1, type EI7).
According to HD 308 and EN 50334, the standard identification is as follows:
Just One Natural
Brown + Blue x Two
3 G Brown + Blue + Yellow/Green
Three times Brown, Grey, and Black
4 G Black + Brown + Grey + Yellow/Green
Brown, Black, Grey, and Blue four times
Five grams of grey, blue, yellow/green, black, and brown
Six or more black digits plus yellow or green
3. The external shell:
Black, flexible rubber of type EM2 according to EN 50363-2-1.
Cable Specifications
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 1,8/3kV
MECHANICAL PERFORMANCE
- Impact resistance: AG2 Medium severity.
WATER PERFORMANCE
- Deep wells
- Drinkable water
- Submersible pumps
- Water resistance: AD8 Submersion.
CHEMICAL PERFORMANCE
- Chemical & Oil resistance: Excellent.
- Grease & mineral oils resistance: Excelente
FIRE PERFORMANCE
- Flame non-propagation based on EN 60332-1 and IEC 60332-1
THERMAL PERFORMANCE
- Maximum service temperature: 90ºC.
- Maximum short-circuit temperature: 250ºC (max. 5 s).
- Minimum service temperature: -40ºC (fixed and protected installations) and -25ºC (mobile use)
APPROVALS
- CE
- RoHS
PACKAGING
- Available in rolls (lengths of 50 and 100 m) and drums.
CONSTRUCTION PRODUCT REGULATION
- Eca
OTHERS
- Meter by meter marking.
APPLICATIONS
- Industrial use.
- Mobile use.
- Robotics.
- Temporary site installations.
- Wind turbines
INSTALLATION CONDITIONS
- Open Air.
International norm
- IEC 60332-1
Reviews