X-VOLT RHZ1
Description
X-VOLT RHZ1 Medium Voltage aluminium or copper cable, XLPE insulation. Configuration options: Cu or Al (OL/2OL). Halogen-free, flame non-propagator, fire non-propagator.
X-VOLT RHZ1 cable performance
Electrical performance
MEDIUM VOLTAGE: 6/10 kV, 8,7/15 kV, 12/20 kV and 18/30 kV.
Standard
IEC 60502-2.
Approvals
AENOR
Thermal performance
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -15ºC
Fire performance (standard configuration)
Halogen free: based on UNE-EN 50267.
(S) Configuration fire performance
Flame non-propagation based on UNE-EN 60332-1.
Halogen free: based on UNE-EN 50267.
Low smoke emission based on UNE-EN 61034. Reaction to fire CPR: Eca, according to EN 50575.
(AS) Configuration fire performance
Flame non-propagation based on UNE-EN 60332-1. Fire non-propagation based on UNE-EN 60332-3 (cat.C).
Halogen free: based on UNE-EN 50267.
Low smoke emission based on UNE-EN 61034. Reaction to fire CPR: Cca, according to EN 50575.
Mechanical performance
Minimum bending radius: x15 cable diameter.
Abrasion-resistant.
Tear-resistant.
Chemical performance
UV Resistant: UNE 211605.
Installation conditions
Open Air.
Buried.
In conduit.
Applications
Distribution networks.
Other
Meter by meter marking.
Optional: rodent-proof and termite-proof.
X-VOLT RHZ1 cable design
Conductor
Aluminium or copper conductor, class 2, based on EN 60228 and IEC 60228. Optionally, with longitudinal sealing (cable type -2OL).
Internal semiconductor
Screen over the conductor, made of thermosetting semiconductor material.
Insulation
Cross-linked polyethylene (XLPE), in dry atmosphere catenary tube, through a triple layer extrusion process.
External semiconductor
Screen over the insulation, made of thermosetting and strippable semiconductor material.
Metallic screen
A screen of copper wires and copper tape, with a minimum cross-section of 16m2.
Longitudinal sealing
Hygroscopic tape completely covering the screen (cable type –OL and -2OL).
(Filling)
(Possible, depending on the configurations).
Outer sheath
External sheath of halogen-free polyolefin, red colour.
X-VOLT HEPRZ1 AL halogen-free polyolefin, red colour. X-VOLT HEPRZ1 AL (S) version is flame-retardant and halogen-free polyolefin, red colour with two grey bands. X-VOLT HEPRZ1 AL (AS) version is fire-retardant and halogen-free polyolefin, red colour with two green bands.
LOW VOLTAGE 0,6/1kV
Maximum conductor temperature: 90ºC.
Water resistance: AD5 Jets
Flame non-propagation based on EN 60332-1 and IEC 60332-1
Industrial use / Public places.
Technology
1. A conductor
Class 5 (flexible) electrolytically annealed copper conductor, in accordance with EN and IEC 60228.
2. Warmth
IEC 60502-1 defines cross-linked polyethylene (XLPE).
In accordance with HD 308, insulated conductors are typically identified as follows:
One Natural
Two x Brown + Blue
3 G Green/Yellow + Brown + Blue
Three x Black + Grey + Brown
(reduced cross-section) 3 x + 1 x Brown + Black + Grey + Blue
4 G Yellow/green + Black + Grey + Brown
Four times: Brown, Black, Grey, and Blue
Five grams of brown, black, grey, blue, and yellow/green
3. The outer sheath
Polyolefin that is Low Smoke Halogen Free (LSHF). The color black.
Cable Specifications
ENVIRONMENTAL PERFORMANCE
-
Chemical
Oil resistance: Acceptable.
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 0,6/1kV
MECHANICAL PERFORMANCE
-
Impact resistance: AG2
Medium severity. -
Minimum bending radius:
x5 cable diameter.
WATER RESISTANCE
- Water resistance: AD8 Submersion.
CHEMICAL PERFORMANCE
- UV Resistant based on EN 50618.
FIRE PERFORMANCE
-
Fire non-propagation based on
EN 60332-3 / IEC 60332-3
/ EN 50399. - Flame non-propagation based on EN 60332-1 and IEC 60332-1
-
Low corrosive gases emission
based on UNE-EN 60754-2 and IEC 60754-2. -
Low smoke emission according
to EN 61034 and IEC 61034: Light transmittance > 80%.
THERMAL PERFORMANCE
-
Impact resistance: AG2 Medium
severity. -
Minimum bending radius: x5
cable diameter.
APPROVALS
- CE
- KEMA KEUR
INSTALLATION CONDITIONS
- Buried
- In conduit.
- Open Air.
National norm / European:
- UNE-EN 60332-1
CONSTRUCTION PRODUCT REGULATION
- B2ca s1a, d1, a1
BASED ON
- IEC 60502-1
International norm
- IEC 60502-1
OTHERS
- Meter by meter marking.