TOPWELD H01N2-D
Description
The special cable for welding.
The TOPWELD H01N2-D is a flexible, harmonized rubber welding cable that is specifically made to transfer high currents between the electrode and the welding generator. Its flexibility facilitates the use of the welding tool and keeps cable knots from forming, which could lead to the internal conductor breaking. Additionally, it can be utilized in conveyor systems, automatic welding, machine tools, and manufacturing or assembly lines, such as those used in auto assembly.
Performance of TOPWELD H01N2-D cables
Electrical functionality
100/100V LOW VOLTAGE
Typical
EN 50525-2-81
Acceptances
CE, RoHS, HAR, and AENOR
Thermal efficiency
85ºC is the maximum conductor temperature.
250ºC is the maximum short-circuit temperature (maximum 5 s).
For mobile use, the minimum service temperature is -20ºC.
Performance of fire
non-propagation of flames according to IEC 60332-1 and EN 60332-1.
Performance of mechanical systems
A minimum cable diameter of x5 is required for bending.
Medium severity AG2 impact resistance.
Performance of chemicals
Resistance to chemicals and oils:
Fantastic.
Resistance to mineral and grease oils:
Fantastic
Other
marker from meter to meter.
Conditions of installation
Outside.
Uses
welding.
industrial use.
usage on the go.
robotics.
conveyors.
Design of TOPWELD H01N2-D cable conductor
Class D (extra-flexible) electrolytically annealed copper, according to EN 50525-2-81.
Insulation
According to EN 50363-2-2, flexible rubber type EM5 is black in color.
LOW VOLTAGE 100/100V
Maximum service temperature: 85ºC.
Conveyors / Industrial use / Mobile use / Robotics / Welding
Flame non-propagation based on EN 60332-1 and IEC 60332-1
EN 60332-1 / EN 60332-3
Technology
1. Class D (extra-flexible) conductor electrolytic copper, according to UNE-EN 50525-2-81.
2. Warmth According to EN 50363-2-2, flexible rubber type EM5 is black in color.
Cable Specifications
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 100/100V
MECHANICAL PERFORMANCE
- Impact resistance: AG2 Medium severity.
- Minimum bending radius: x5 cable diameter.
CHEMICAL PERFORMANCE
- Chemical & Oil resistance: Excellent.
- Grease & mineral oils resistance: Excelente
FIRE PERFORMANCE
- Flame non-propagation based on EN 60332-1 and IEC 60332-1
THERMAL PERFORMANCE
- Maximum service temperature: 85ºC.
- Maximum short-circuit temperature: 250ºC (max. 5 s).
- Minimum service temperature: -20ºC.
APPROVALS
- AENOR
- CE
- HAR
- RoHS
OTHERS
- Meter by meter marking.
APPLICATIONS
- Conveyors
- Mobile use.
- Industrial use.
- Robotics
- Welding.
BASED ON
- EN 50525-2-81
INSTALLATION CONDITIONS
- Open Air.
National norm / European:
- EN 60332-1 / EN 60332-3
International norm
- IEC 60332-1

Reviews
There are no reviews yet.