TOPFLEX VV-F H05VV-F
Description
TOPFLEX VV-F H05VV-F cable has been specially designed for connecting small home appliances such as vacuum cleaners, washing machines, refrigerators, etc. It is recommended for household installations and can also be used for light mobile services. These cables are also suitable for fixed applications in furniture, wall partitions, and in hollow spaces of prefabricated building parts.
TOPFLEX VV-F H05VV-F cable performance
Electrical performance
LOW VOLTAGE 300/500 V
Standard
EN 50525-2-11 / IEC 60227
Approvals
HAR / AENOR / CE / RoHS / SEC
CPR Construction Product Regulation
Eca
Thermal performance
Maximum conductor temperature: 70ºC.
Maximum short-circuit temperature: 160ºC (max. 5 s).
Minimum service temperature: 5ºC.
Fire performance
Flame non-propagation based on EN 60332-1 and IEC 60332-1.
Reduced emission of halogens. Chlorine <15%.
Reaction to fire CPR: Eca, according to EN 50575.Mechanical performance
Minimum bending radius: 3 x cable Ø (Ø cable <12 mm2). 4 x cable Ø (Ø cable ≥12 mm2).
Impact resistance: AG2 Medium severity.
Chemical performance
Chemical & Oil resistance: Good.
Water performance
Water resistance: AD5 Jets.
Other
Meter by meter marking.
Installation conditions
Open Air.
In conduit.
Applications
Mobile use.
Domestic use.
Domestic appliances.
Temporary appliances.
Packaging
Available in rolls (lengths of 50 and 100 m) and drums.
TOPFLEX VV-F H05VV-F cable design
Conductor
Electrolytic annealed copper, class 5 (flexible), based on EN 60228 and IEC 60228.
Insulation
Flexible PVC type TI2 according to EN 50363-3.
The standard identification of insulated conductors, according to UNE 21089-1 and HD 308 is the following:
2x Brown + Blue
3G Brown + Blue + Yellow/green
4G Brown + Black + Grey + Yellow/green
5G Brown + Black + Grey + Blue + Yellow/green
Outer sheath
Flexible PVC type TM2 according to EN 50363-4-1. Standard colors are grey, white and black. Other colors available on request.
LOW VOLTAGE 300/500 V
EN 60332-1
Eca
Maximum service temperature: 60ºC.
Domestic appliances / Domestic use / Mobile use / Temporary appliances
Technology
1. Conductor
Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.
2. Insulation
Flexible PVC.
The standard identification of insulated conductors is the following:
2x Brown + Blue
3G Brown + Blue + Yellow/green
4G Brown + Black + Grey + Yellow/green
5G Brown + Black + Grey + Blue + Yellow/green
3. Outer sheath
Flexible PVC. Standard colours are grey, white and black. Other colours available on request.
Cable Specifications
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 300/500 V
MECHANICAL PERFORMANCE
- Impact resistance: AG2 Medium severity.
- Minimum bending radius: X3 cable diameter (cable <12 mm) X4 cable diameter (cable ≥12 mm)
WATER PERFORMANCE
- Water resistance: AD5 Jets.
CHEMICAL PERFORMANCE
- Chemical & Oil resistance: Good.
FIRE PERFORMANCE
- Flame non-propagation based on EN 60332-1 and IEC 60332-1
- Reaction to fire CPR: Eca, according to EN 50575.
- Reduced halogen emission. Chlorine <15%.
THERMAL PERFORMANCE
- Maximum service temperature: 70ºC.
- Maximum short-circuit temperature: 160ºC (max. 5 s).
- Minimum service temperature: 5ºC.
APPROVALS
- AENOR
- CE
- HAR
- RoHS
- SEC
BASED ON
- EN 50525-2-11 / IEC 60227
CONSTRUCTION PRODUCT REGULATION
- Eca
International norm
- IEC 60332-1
APPROVALS
- Domestic appliances.
- Domestic use.
- Mobile use.
- Temporary site installations.
PACKAGING
- Available in rolls (lengths of 50 and 100 m) and drums.
INSTALLATION CONDITIONS
- Buried
- In conduit.
- Open Air.
National norm / European:
- EN 60332-1 / EN 60332-3
OTHERS
- Meter by meter marking.
Reviews