TOXFREE ZH OUTDOOR H07Z1-K (AS) Cu/Sn
Description
A cable specifically made for ground connections in outdoor installations is Toxfree® ZH Outdoor H07Z1-K (AS) Cu/Sn. When joining metals with different normal potentials, this cable's tinned copper conductor and unique outer sheath compounds prevent galvanic pairs and make it extremely resistant to corrosion and ultraviolet (UV) degradation. According to solar standard EN 50618, it is a halogen-free cable with the highest CPR classification (B2ca-s1a,d1,a1) and UV protection.
Performance of TOXFREE® ZH OUTDOOR H07Z1-K (AS) Cu/Sn cable
Electrical functionality
450/750 V LOW VOLTAGE
Typical
UNE 211002 / EN 50525-3-31
Acceptances
HAR, CE, RoHS, AENOR, and BUREAU VERITAS
Regulation of CPR Construction Products
B2ca s1a, d1, a1
Thermal efficiency
70ºC is the maximum conductor temperature.
160ºC is the maximum short-circuit temperature (maximum 5 s).
For protected and fixed installations, the minimum service temperature is -40ºC.
Performance of fire
In accordance with EN 60332-1 and IEC 60332-1, flames do not spread.
According to EN 60332-3-24, IEC 60332-3-24, and EN 50399, fire does not spread.
LSHF (Low Smoke Halogen Free) in accordance with IEC 60754-1 and EN 60754-1.
Low smoke emissions in accordance with IEC 61034 and EN 61034: Transmittance of light > 80%
low emissions of corrosive gases in accordance with IEC 60754-2 and EN 60754-2.
In accordance with EN 50575, the response to fire CPR is B2ca s1a, d1, a1.
Performance of mechanical systems
Cable diameter x5 is the minimum bending radius.
Performance of chemicals
Excellent resistance to chemicals and oil.
Performance of water
AD3 Sprays are water resistant.
Other
marking from meter to meter. (starting at 10 mm2)
Conditions of installation
in a conduit.
Packing
Robust drums and boxes.
Conductor
Cu/Sn cable design conductor TOXFREE ZH OUTDOOR H07Z1-K (AS)
Class 5 (flexible) electrolytically annealed tinned copper, in accordance with EN and IEC 60228.
Insulation
UV-resistant polyolefin, type TI7, as defined by EN 50363-7.
Insulated conductors are typically identified as follows:
Green/Yellow RAL 6018/1021
Additional colors can be requested.
LOW VOLTAGE 450/750 V
B2ca -s1a, d1, a1
Water resistance: AD3 Sprays
AENOR, CE, HAR, RoHS, BUREAU VERITAS
Minimum bending radius: x5 cable diameter
Technology
Conductor:
Electrolytically annealed tinned copper, class 5 (flexible) as defined by IEC 60228 and EN 60228.
2. Insulation
UV-resistant polyolefin, type TI7, in accordance with EN 50363-7.
Insulated conductors are typically identified as follows:
Green/yellow RAL 6018/1021
Additional colors can be requested.
Cable Specifications
CHEMICAL PERFORMANCE
- Chemical & Oil resistance: Excellent.
FIRE PERFORMANCE
- Fire non-propagation according to EN 60332-3-24 and IEC 60332-3-24.
- Flame non-propagation based on EN 60332-1 and IEC 60332-1
- Low smoke emission according to EN 61034 and IEC 61034: Light transmittance > 80%.
- LSHF (Low Smoke Halogen Free) based on UNE-EN 60754-1 and IEC 60754-1.
MECHANICAL PERFORMANCE
- Minimum bending radius: x5 cable diameter.
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 450/750 V
THERMAL PERFORMANCE
- Maximum service temperature: 70ºC.
- Maximum short-circuit temperature: 160ºC (max. 5 s).
- Minimum service temperature: -40ºC (fixed and protected installations)
WATER PERFORMANCE
- Water resistance: AD3 Sprays
APPROVALS
- AENOR
- BUREAU VERITAS
- CE
- HAR
- RoHS
OTHERS
- Meter by meter marking. (from 10mm2 onwards)
BASED ON
- EN 50525-3-31
- UNE 211002
CONSTRUCTION PRODUCT REGULATION
- B2ca s1a, d1, a1
PACKAGING
- 1015 0,75-6 mm2 High resistant boxes
INSTALLATION CONDITIONS
- In conduit.
- On tray
- Open Air.