TOPFLAT H05VVH6-F & H07VVH6-F
Description
TOPFLAT H05VVH6-F and H07VVH6-F are flat cables designed especially for cranes, lifts, hoists, drum reeling, and conveyor systems. It is not recommended to stack wires on top of each other during installation. The cable can hang up to 35 meters and draw out at a maximum speed of 1.6 meters per second.
The TOPFLAT H05VVH6-F and H07VVH6-F cables' performance
Electrical performance
LOWEST VOLTAGE: 300/500 V, 450/750 V
For H05VVH6-F (up to 1 mm2), the nominal voltage is 300/500 · V, and for H07VVH6-F (from 1,5 mm2), it is 450/750 V.
Typical
HD 359, EN 50214, and IEC 60277-6
Acceptances
CE, RoHS, AENOR, and HAR
Efficiency of heat
The maximum conductor temperature is 70ºC.
The highest short-circuit temperature (maximum 5 s) is 160ºC.
The minimum service temperature is 0ºC.
Fire performance
flames that do not spread in accordance with IEC 60332-1 and EN 60332-1.
reduced halogen emissions. 15% or less chlorine.
Mechanical system performance
The minimum pulley bending radius (to 20 ± 10ºC) is ten times smaller than that of gantry cranes. The size of the pulley was ten times smaller. Five times smaller in free motion
The AG2 impact resistance is medium.
Chemical performance
Oil and chemical resistance: Acceptable.
Water's performance
Water does not harm AD5 Jets.
Other
meter-to-meter marker.
Applications
industrial use.
use while travelling.
bridge cranes.
Lifts, lifts.
conveyors.
TopFLAT H05VVH6-F and H07VVH6-F cable designs
The conductor
Electrolytic copper of class 5 (flexible), according to EN 60228 and IEC 60228.
Insulation
Flexible PVC type TI2 (EN 50363-3).
Insulated conductors are often identified as follows in compliance with HD 308 and EN 50334:
4 G: Brown, Grey, Black, and Green/Yellow
At least six conductors with black and green or yellow numbers
Lay-upInsulated conductors are positioned parallel to each other to form a flat wire.
Sheath outside
Type TM2 is a black, flexible PVC outer sheath that complies with EN 50363-4-1. The ripcord can be used to gently tear the outer sheath.
LOW VOLTAGE 300/500 V 450/750 V
Maximum service temperature: 70ºC.
HD 359 – EN 50214
Flame non-propagation based on EN 60332-1 and IEC 60332-1
EN 60332-1 / EN 60332-3
Minimum bending radius on pulleys (to 20 ± 10oC): Festooned as in gantry cranes: 10 x smaller dimension · Deflected by pulleys: 10 x smaller dimension · Free movement: 5 x smaller dimension
Technology
1. Class 5 (flexible) conductor electrolytic copper, according to EN and IEC 60228.
2. PVC insulation that is flexible.
Insulated conductors are typically identified as follows:
4 G Yellow/green + Black + Grey + Brown
At least six conductors Numbered in black plus yellow/green
3. The black, flexible PVC outer sheath. Without causing any harm to the screen, the ripcord enables you to gently separate the outer sheath and remove it.
Cable Specifications
ENVIRONMENTAL PERFORMANCE
- Chemical & Oil resistance: Acceptable.
FIRE PERFORMANCE
-
Fire non-propagation based on
EN 60332-3 / IEC 60332-3
/ EN 50399. - Flame non-propagation based on EN 60332-1 and IEC 60332-1
-
Low corrosive gases emission
based on UNE-EN 60754-2 and IEC 60754-2. -
Low smoke emission according
to EN 61034 and IEC 61034: Light transmittance > 80%.
WATER RESISTANCE
- Water resistance: AD8 Submersion.
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 300/500 V 450/750 V
- Rated Voltage: H05V-K (up to 1 mm2): 300/500 V. H07V-K (from 1,5 mm2 onwards): 450/750 V.
MECHANICAL PERFORMANCE
- Impact resistance: AG2 Medium severity.
THERMAL PERFORMANCE
- Maximum service temperature: 70ºC.
- Maximum short-circuit temperature: 160ºC (max. 5 s).
- Minimum service temperature: 0ºC.
APPROVALS
- AENOR
- CE
- HAR
- RoHS
- UNE-EN 60332-1
BASED ON
- HD 359 – EN 50214
INSTALLATION CONDITIONS
- Meter by meter marking.
APPLICATIONS
- Conveyors
- Cranes
- Elevators, lifts.
- Industrial use.
- Mobile use.
International norm
- IEC 60332-1
National norm / European:
- UNE-EN 60332-1
Reviews
There are no reviews yet.