TOXFREE PLUS 331 ZH RZ1-K (AS+)
Description
LSHF and fire resistant power cable, for emergency circuits.
TOXFREE Plus 331 ZH RZ1-K (AS+) is a fire resistant cable, specially designed to ensure the power supply to emergency circuits in the event of fire. During a fire you need critical circuits to work for life safety (signaling lights, fume extractors, acustic alarms, water pumps, etc) and a secure plant shutdown. For this reason, its use is highly recommended in public places such as: hospitals, tunnels, offices, production plants, laboratories, hotels, etc.
TOXFREE PLUS 331 ZH RZ1-K (AS+) cable performance
Electrical performance
LOW VOLTAGE 0,6/1kV
Standard
IEC 60502-1
Approvals
CE/ RoHS
CPR Construction Products Regulations B2ca-s1a, d1, a1 (according to cross-section) or Cca-s1b,d1,a1 (according to cross-section).Thermal performance
Maximum conductor temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations).
Mechanical performance
Minimum bending radius: x5 cable diameter.
Impact resistance: AG2 Medium severity.
Chemical performance
Chemical & Oil resistance: Acceptable.
Water performance
Water resistance: AD5 Jets.
Fire performance
Flame non-propagation based on EN 60332-1 and IEC 60332-1.
Fire non-propagation based on EN 60332-3, IEC 60332-3 and EN 50399.
Fire resistant: (PH120) mínimum 120 minutes at 840ºC: Based on EN 50200 and IEC 60331-2 for Ø cable ≤ 20 mm.
Based on EN 50362 and IEC 60331-1 for Ø cable > 20 mm. 180’ at 950ºC (cat C) category C,W & Z based on BS6387.
Fire resistant 180’ at 950ºC (cat C) category C,W & Z based on BS6387 (300/500V).
LSHF (Low Smoke Halogen Free) based on EN 60754-1 and IEC 60754-1.
Low smoke emission based on EN 61034 and IEC 61034: Light transmittance > 60%
Low corrosive gases emission based on EN 60754-2 and IEC 60754-2.
Other
Meter by meter marking.
Installation conditions
Open Air.
Buried.
In conduit.
Applications
Industrial use.
Emergency circuits
Public places.
TOXFREE PLUS 331 ZH RZ1-K (AS+) cable design
Conductor
Electrolytic annealed copper, class 5 (flexible), based on EN 60228 and IEC 60228.
Insulation
Mica tape + Cross-linked polyethylene type DIX-3 according to HD 603.
The standard identification of insulated conductors according to HD 308 is the following:
1 x Natural
2x Blue + Brown
3 x Blue + Brown + Grey
3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section)4 x Brown + Black + Grey + Blue
5 G Brown + Black + Grey + Green/yellow + Blue
Outer sheath
Low Smoke Halogen Free (LSHF) polyolefin. Orange color, non-toxic, fire retardant and fire resistant.
LOW VOLTAGE 0,6/1kV
Maximum conductor temperature: 90ºC.
Water resistance: AD5 Jets
Flame non-propagation based on EN 60332-1 and IEC 60332-1
Industrial use / Public places.
Technology
1. Conductor
Electrolytic annealed copper conductor, class 5 (flexible), based on EN 60228 and IEC 60228.
2. Insulation
Cross-linked polyethylene (XLPE) according to IEC 60502-1.
The standard identification of insulated conductors according to HD 308 is the following:
1 x Natural
2 x Blue + Brown
3 G Blue + Brown + Yellow/green
3 x Brown + Black + Grey
3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section)
4 G Brown + Black + Grey + Yellow/green
4 x Brown + Black + Grey + Blue
5 G Brown + Black + Grey + Blue + Yellow/green
3. Outer sheath
Low Smoke Halogen Free (LSHF) polyolefin. Black colour.
Cable Specifications
ENVIRONMENTAL PERFORMANCE
-
Chemical
Oil resistance: Acceptable.
ELECTRICAL PERFORMANCE
- LOW VOLTAGE 0,6/1kV
MECHANICAL PERFORMANCE
-
Impact resistance: AG2
Medium severity. -
Minimum bending radius:
x5 cable diameter.
WATER RESISTANCE
- Water resistance: AD8 Submersion.
CHEMICAL PERFORMANCE
- UV Resistant based on EN 50618.
FIRE PERFORMANCE
-
Fire non-propagation based on
EN 60332-3 / IEC 60332-3
/ EN 50399. - Flame non-propagation based on EN 60332-1 and IEC 60332-1
-
Low corrosive gases emission
based on UNE-EN 60754-2 and IEC 60754-2. -
Low smoke emission according
to EN 61034 and IEC 61034: Light transmittance > 80%.
THERMAL PERFORMANCE
-
Impact resistance: AG2 Medium
severity. -
Minimum bending radius: x5
cable diameter.
APPROVALS
- CE
- KEMA KEUR
INSTALLATION CONDITIONS
- Buried
- In conduit.
- Open Air.
National norm / European:
- UNE-EN 60332-1
CONSTRUCTION PRODUCT REGULATION
- B2ca s1a, d1, a1
BASED ON
- IEC 60502-1
International norm
- IEC 60502-1
OTHERS
- Meter by meter marking.
Reviews